fireangel carbon monoxide alarm user manual

Welcome to the FireAngel Carbon Monoxide Alarm user manual. This guide provides essential information for safe installation‚ operation‚ and maintenance of your CO detector. Ensure your home stays protected with early detection and loud alerts.
1.1 Overview of the FireAngel Carbon Monoxide Alarm
The FireAngel Carbon Monoxide Alarm is a compact‚ lightweight device designed to detect dangerous CO levels in your home. It continuously monitors for carbon monoxide‚ providing early warnings and resisting false alarms from household contaminants. With a loud 85dB alert and LED indicators‚ it ensures prompt notifications. Certified to BS EN 50291:2001‚ it offers trusted protection for your family with advanced detection technology.
1.2 Importance of Carbon Monoxide Detection
Carbon monoxide is a silent killer‚ odorless and colorless‚ making it nearly undetectable without a reliable alarm. Early detection is crucial to prevent poisoning‚ which can be fatal. The FireAngel Carbon Monoxide Alarm ensures continuous monitoring‚ providing vital seconds to react and protect your family from potential tragedies.
1.3 Purpose of the User Manual
This manual is designed to guide users in installing‚ operating‚ and maintaining their FireAngel Carbon Monoxide Alarm. It ensures proper use‚ highlights safety measures‚ and provides troubleshooting tips‚ helping users maximize the device’s effectiveness in protecting their homes and families from carbon monoxide threats.
Features of the FireAngel Carbon Monoxide Alarm
The FireAngel CO alarm offers continuous CO level monitoring‚ an 85dB loud alert‚ LED status indicators‚ and resistance to false alarms from household contaminants‚ ensuring reliable protection for your home.
2.1 Continuous Monitoring of Carbon Monoxide Levels
The FireAngel CO alarm continuously monitors carbon monoxide levels‚ ensuring immediate detection of dangerous concentrations. Its advanced sensor technology provides real-time updates‚ offering constant protection against potential threats in your home.
2.2 Early Warning System for Toxic CO Levels
The FireAngel CO alarm features an early warning system that detects low levels of carbon monoxide‚ providing timely alerts before dangerous concentrations arise. This ensures you have ample time to respond and stay safe from potential CO poisoning risks.
2.3 Resistance to False Alarms from Household Contaminants
Designed to minimize false alarms‚ the FireAngel CO alarm ignores common household contaminants like cooking fumes or steam. This advanced feature ensures reliable performance‚ reducing unnecessary alerts and providing peace of mind for users.
2.4 Loud 85dB Alarm for Emergency Alerts
The FireAngel CO alarm features a loud 85dB alert at 1 meter‚ ensuring clear warning in emergencies. This high-decibel output is designed to be heard throughout the home‚ providing immediate notification of dangerous CO levels for timely action and safety.
2.5 LED Indicators for Power and Alarm Status
The FireAngel CO alarm includes LED indicators to show power status and alarm activation. These LEDs provide visual confirmation of the device’s operational state‚ ensuring easy monitoring and peace of mind with clear status updates for both power and alarm conditions.
Installation Guide
Activate the alarm by removing the disabling tab. Install on walls or ceilings‚ following manufacturer guidelines for placement and height. Ensure compliance with safety standards for optimal protection.
3.1 Activating the Alarm
To activate the FireAngel CO alarm‚ locate and remove the disabling tab from the back of the device. This action powers on the alarm‚ initiating continuous carbon monoxide monitoring. Ensure the tab is fully removed for proper functionality and to enable accurate detection of CO levels in your home.
3.2 Recommended Placement and Positioning
Place the FireAngel CO alarm in areas like bedrooms and living spaces for optimal coverage. Mount it on a wall or ceiling‚ at least 1 meter away from fuel-burning appliances. Avoid installing near windows‚ doors‚ or draughty areas to ensure accurate detection and minimize false alarms.
3.3 Interconnecting with Other Alarms
Interconnect your FireAngel CO alarm with up to 11 other FireAngel smoke or heat alarms using the SmartBridge connector. This creates a network where all alarms activate simultaneously‚ ensuring comprehensive safety throughout your home. Refer to the manual for wiring instructions and compatibility details.
Maintenance and Testing
Regularly test your FireAngel CO alarm by pressing the test button weekly. Vacuum the sensor monthly to ensure optimal performance. Inspect LED indicators for proper function and replace batteries as needed to maintain reliability and safety.
4.1 Weekly Testing of the Alarm
Test your FireAngel CO alarm weekly by pressing the test button for 5 seconds. This ensures the sensor and alarm are functioning correctly. A loud 85dB tone confirms the alarm is operational. Regular testing is crucial for maintaining home safety and ensuring early detection of carbon monoxide leaks.
4.2 Monthly Vacuum Cleaning
Clean your FireAngel CO alarm monthly using a soft brush or vacuum cleaner on a low setting. This prevents dust buildup that could interfere with sensor accuracy. Avoid using liquids or harsh chemicals. Regular cleaning ensures optimal performance and reliable detection of carbon monoxide levels in your home.
4.3 Regular Inspection of LED Indicators
Inspect the LED indicators monthly to ensure proper function. The green LED indicates power‚ while the red LED signals an alarm or error. If LEDs are dim or not lit‚ check connections or replace the alarm if necessary to maintain reliable carbon monoxide detection and alerts.
Troubleshooting Common Issues
Identify common issues like false alarms or error codes. Refer to the beeping patterns and LED indicators in the manual for diagnostics. Contact FireAngel support for assistance.
5.1 Understanding Error Codes and Beeping Patterns
Understand error codes and beeping patterns to diagnose issues. Refer to the manual for specific codes and sounds‚ such as three beeps indicating a fault or two beeps for low battery. Consult the troubleshooting guide or contact FireAngel support for assistance with resolving alarms.
5.2 Resolving False Alarms
If a false alarm occurs‚ ensure no household contaminants like cooking fumes or steam are present. Press the test/hush button to silence the alarm temporarily. Clean the detector with a vacuum to remove dust or debris. If the issue persists‚ consider relocating the alarm or consulting the troubleshooting guide.
5.3 Repairing or Replacing the Alarm
If the alarm shows error codes or persistent beeping‚ check for damage. Press the test button to verify functionality. If faulty‚ replace the unit immediately. Contact FireAngel technical support for assistance or warranty claims. Ensure a replacement meets safety standards to maintain protection against carbon monoxide threats effectively.
Compliance and Certification
This alarm complies with BS EN 50291:2001 standards‚ ensuring reliability. It holds a Certificate of Compliance and is backed by a comprehensive product warranty.
6.1 Meets BS EN 50291:2001 Standards
The FireAngel Carbon Monoxide Alarm is certified to BS EN 50291:2001‚ ensuring it meets stringent European safety standards for CO detection. This certification guarantees reliable performance‚ accurate detection‚ and compliance with regulatory requirements‚ providing users with peace of mind and enhanced home safety.
6.2 Certificate of Compliance
Your FireAngel Carbon Monoxide Alarm comes with a Certificate of Compliance‚ confirming it meets all necessary safety standards. This document assures users of the product’s reliability and adherence to regulations‚ ensuring it functions effectively to protect lives and property from carbon monoxide threats.
6.4 Product Warranty Information
The FireAngel Carbon Monoxide Alarm is backed by a comprehensive warranty. For details on warranty duration‚ coverage‚ and terms‚ refer to the product documentation or contact FireAngel’s technical support team at technicalsupport@fireangel.co.uk or call 0330 094 5830.
Interconnectivity with Other Devices
The FireAngel CO alarm can interconnect with up to 11 other smoke‚ heat‚ or CO alarms via the I connector‚ ensuring a unified safety system for your home.
7.1 Connecting to Smoke and Heat Alarms
Connect your FireAngel CO alarm with smoke and heat alarms via the I connector for seamless integration. This interconnectivity ensures all safety devices activate simultaneously‚ enhancing home safety by providing comprehensive detection and alerts for multiple hazards‚ ensuring a unified response system throughout your property.
7.2 Maximum Number of Interconnected Alarms
The FireAngel CO alarm can interconnect with up to 11 other alarms‚ including smoke‚ heat‚ or additional CO detectors. This interconnected system provides enhanced safety by ensuring all alarms activate simultaneously‚ offering comprehensive protection throughout your home with a maximum network capacity of 12 devices.
7.3 Benefits of a Connected Safety System
A connected safety system ensures all alarms activate simultaneously‚ providing early detection and warning. This interconnected network enhances safety by alerting everyone in the home instantly‚ offering comprehensive protection and peace of mind with seamless communication between devices.
Emergency Procedures
Stay calm and exit the building immediately when the alarm sounds. Do not re-enter until authorities confirm it is safe. Contact the UK Gas Emergency Service at 0800 111 999 if needed. Follow all safety guidelines in this manual.
8.1 What to Do When the Alarm Sounds
Stay calm and immediately evacuate the premises. Do not re-enter the building until authorities confirm it is safe. Open windows for ventilation if possible. Contact the UK Gas Emergency Service at 0800 111 999 if you suspect a leak. Follow all safety guidelines outlined in this manual.
8.2 Evacuation and Safety Measures
Evacuate immediately and stay outside until authorities confirm it is safe to re-enter. Do not attempt to locate the source of CO. Ensure all occupants‚ especially vulnerable individuals‚ exit safely. Avoid re-entry until emergency services declare the area safe and CO levels are confirmed to be normal.
8.3 Contacting Emergency Services
Immediately contact emergency services at 0800 111 999 (UK Gas Emergency Helpline) if the alarm sounds. This toll-free number operates 24/7 for urgent assistance. Stay on the line and follow instructions carefully. Do not re-enter your home until professionals confirm it is safe.
Technical Specifications
The FireAngel CO alarm features an 85dB loud alert‚ LED status indicators‚ and meets BS EN 50291:2001 standards. It operates on a 10-year battery life‚ ensuring reliable detection and safety.
9.1 Alarm Sensitivity and Detection Range
The FireAngel CO alarm detects low CO levels‚ providing early warnings. It accurately monitors concentrations‚ ensuring reliable detection within specified ranges to protect against toxic exposure‚ with sensitivity optimized for home environments. This ensures timely alerts for safety.
9.2 Power Requirements
The FireAngel CO alarm operates on a 10-year sealed battery‚ ensuring continuous protection without battery replacements. It features a low-power indicator to alert you when the battery level is critical‚ guaranteeing reliable operation and maintaining your safety at all times with minimal maintenance required.
9.3 Dimensions and Weight
The FireAngel CO-9B alarm measures approximately 110mm in diameter and 40mm in depth‚ making it compact for easy installation. It weighs around 130g‚ ensuring lightweight and hassle-free placement while maintaining robust performance and reliability for home safety. Its sleek design fits seamlessly into any interior setting.
Congratulations on choosing the FireAngel Carbon Monoxide Alarm‚ a reliable and efficient safety solution for your home. Always follow the manual for optimal performance and safety.
10.1 Summary of Key Features and Benefits
The FireAngel Carbon Monoxide Alarm offers continuous CO monitoring‚ an 85dB alarm‚ LED indicators‚ and resistance to false alarms. Its compact design and easy installation ensure comprehensive protection‚ providing peace of mind for you and your family with reliable performance and compliance with safety standards.
10.2 Final Tips for Safe Use
Always test your FireAngel CO alarm weekly and vacuum it monthly. Ensure proper placement‚ avoid obstructing airflow‚ and never ignore alerts. Replace batteries or units as specified and keep the user manual handy for quick reference. Stay vigilant to protect your family and home from CO risks.
Contact Information
FireAngel Ltd.‚ The Technocentre‚ Puma Way‚ Coventry CV1 2TT England.
Contact us for technical support: 0330 094 5830 or email technicalsupport@fireangeltech.com. Visit our website at www.fireangel.co.uk for assistance.
11.1 FireAngel Technical Support Details
Contact FireAngel’s technical support team for assistance with your carbon monoxide alarm. Call us at 0330 094 5830 or email technicalsupport@fireangeltech.com. Our experts are available to address any questions or concerns you may have regarding installation‚ troubleshooting‚ or maintenance of your device.
11.2 Website and Email for Further Assistance
Visit the official FireAngel website at www.fireangel.co.uk for comprehensive support resources‚ product manuals‚ and troubleshooting guides. For further assistance‚ email technicalsupport@fireangel.co.uk. Our team is dedicated to ensuring your safety and providing expert support for all your carbon monoxide alarm needs.
Leave a Reply
You must be logged in to post a comment.